INSTALLER INSTRUCTIONS
10. Discharging combustion products
(exhaust)
Discharge of combustion products must be ensured through hoods connected to an
efficient natural draught flue, or through a forced exhaust.
An efficient exhaust system requires an accurate design by a specialist that is ap-
proved for this work, following positions and distances contained in regulations.
IMPORTANT: At the end of the intervention the installer must issue a conformity
certificate.
11. Adapting to different types of gasses
Gas
type
Burner
Nominal
power
(KW)
Rated con-
sumption
(g/h)
Injector
(ø mm)
Min. nominal
power
(KW)
Series No. Ref.
LPG GAS
G30/G31 28÷30/37 mbar
II
2 Auxiliary 1,00 73 0,50 0,52
3 Semi-quick 1,75 127 0,65 0,52
4 Quick 2,70 196 0,80 0,90
5 Triple crown 3,50 254 0,95 1,80
10 Dual 4,50 328 i 0.46 / and 0.66 i 0.46 / and 0.66
III
6 Auxiliary 1,10 80 0,52 0,52
7 Semi-quick 1,75 127 0,65 0,52
8 Quick 3,00 218 0,85 0,90
9 Triple crown 3,80 276 0,98 1,80
AE
11 Auxiliary 1,00 73 0,50 0,52
12 Semi-quick 1,75 127 0,65 0,52
13 Quick 3,00 218 0,85 0,90
14 Dual gear 5,00 364 i 0.46 / and 0.95 i 0.30 / and 1.40